## Nomenclature for Experiment
### Flange nomenclature
1) F1=Flange 1 = Acylic flange having inner diameter= 14.76mm and thicness= 15.28mm
2) F2A=Flange 2 = Acylic flange having inner diameter= 12mm and thicness= 11.9mm
3) F3=Flange 3 = Acylic flange having inner diameter= 29.86mm and thicness=15.28mm
4) F4=Flange 4 = Acylic flange having inner diameter= 19.86mm and thicness= 19.24mm
5) F5S=Flange 5 = Stainless steal flange having inner diameter=11.55mm and thicness= 11.48mm
6) SS Flange-6= Stainless steal flange having inner diameter=9.86mm and thicness= 7.96mm
### Nozzle Nomenclature
1) Make in photonics lab and redrilled in chemical department(Chemical Nozzle)= Nozzle 1=N1
#### Nozzle 1 diameter= 0.734 mm=N1



**2) Make and drilled in Mechanical department workshop(Mechanical Nozzle)= Nozzle 2=N2**


### Nozzle 2 diameter= 720 micrometer=N2
$$Area=4.07*10^{-7} m^{2}$$
**3) Make in photonics lab and drilled in sameer khandekar lab (Bhrigunath )= Nozzle 3=N3**




#### Nozzle 3 diameter= 547 micrometer
$$Area=2.827*10^{-7} m^{2}$$

## Pixel information for flange
1) F1N2 =
2) F2N1 = 8.5 Pixels/mm
3) F2N2 = 8.8 Pixels/mm
4) F2N3 = 8.3 Pixels/mm
5) F3N2 =
6) F4N2 = 8.502 Pixels/mm
7) F5SN2 = 8.3024 Pixels/mm
8) F6SN2 = 49.35 Pixel/mm
## Date-26 april24
## Two nozzle used in the experiment one is called as bigger nozzle other is called as smaller nozzle
1) Bigger nozzle


Average diameter of bigger dia from inside =1.040mm
Average diameter of bigger dia from outside= 1.028mm
2) Smaller Diameter


Average diameter of smaller dia from inside= 0.544mm
Average diameter of smaller dia from outside= 0.604mm
SS Flange-1 (thickness 11.48mm, Diameter 11.8mm)
SS Flange-2 (thickness 12.19mm, Diameter 19.8mm)
SS Flange-3 (thickness 20mm, Diameter 11.9mm)