# Finding the right limits for the browser node
Identify errors
repro: 2 browser nodes connected to 1 relay node
no limits set for identify
regular identify

webrtc-direct connection to relay node is made successfully
relayed multiaddress is set
I think this happens when creating a webrtc stream between browser nodes?
after seeing this set
maxInboundStreams: 2,
maxOutboundStreams: 2,
then I see
identify push

same point as prev, no webrtc connection yet
no signaling stream start either
and set
maxPushOutgoingStreams: 2,
maxPushIncomingStreams: 2,
after that settting, webrtc connection is succesfully established
What are the exact limits we need?
that was with 2 browser nodes and 1 relay node
lets try with 10 browser nodes
these limits work for 10 browser nodes
however after running for a little while I see

as well as

on different browser nodes
I also see errors like