# TestReport for CDCFE-Fanout-Baord V0.1: <br> Measurement and Grounding issue ## 1. 1-Vpp seems to be fine * No chassis, No others grounding Yellow: Input/FuncGen-ch2 Blue: Ch1-out/FanoutBaord Red: Ch8-out/FanoutBaord * OPA2674 @1Vpp/10MHz \<External Resistor\> * ![](https://i.imgur.com/IWRS7eO.png) * OPA3692 @1Vpp/10MHz \<Fixed-Gain/IC internal Resistor\> * ![](https://i.imgur.com/YMvUOcH.png) * No chassis, No others grounding ## 2. 0.1-Vpp has noise which seems to be due to bad grounding in Lab-521: <br> building grounding (GND in 3 pole power socket) * OPA2674 @0.1pp/10MHz * ![](https://i.imgur.com/gmb4bMx.png) * OPA3692 @0.1Vpp/10MHz * ![](https://i.imgur.com/Yl2bp9A.png) * OPA2674 @0.1pp/1MHz * ![](https://i.imgur.com/UAd46lt.png) * OPA3692 @0.1Vpp/1MHz * ![](https://i.imgur.com/TZktZJ4.png) Too bad on low voltage(0.1Vpp):( ## 3. Experiment in Lab-510: <br> Independent grounding * OPA2674 @0.1pp/10MHz * ![](https://i.imgur.com/0DVxGQg.png) * OPA3692 @0.1Vpp/10MHz * ![](https://i.imgur.com/4Bj97iy.png) * OPA2674 @0.1pp/1MHz * ![](https://i.imgur.com/nDU0R8d.png) * OPA3692 @0.1Vpp/1MHz * ![](https://i.imgur.com/6wUuiVg.png) Good! Result is the almost same to simulation ;) ## 4. Experiment in Lab-521: <br> (empty VME)chassis grounding ![](https://i.imgur.com/VMhpvWS.png) * OPA2674 @0.1pp/10MHz * ![](https://i.imgur.com/mt8yUJs.png) * OPA3692 @0.1Vpp/10MHz * ![](https://i.imgur.com/D7tH45l.png) * OPA2674 @0.1pp/1MHz * ![](https://i.imgur.com/MqiPFv5.png) * OPA3692 @0.1Vpp/1MHz * ![](https://i.imgur.com/KNhnFwG.png) A little improvement, 10 MHz is also bad ## 5. Experiment in Lab-521: <br> building grounding rod <br> (seems to has lots of people used in this building) ![](https://i.imgur.com/VY5dHS1.png) * OPA2674 @0.1pp/10MHz * ![](https://i.imgur.com/4mHERIz.png) * OPA3692 @0.1Vpp/10MHz * ![](https://i.imgur.com/rUSZ1aY.png) * OPA2674 @0.1pp/1MHz * ![](https://i.imgur.com/tSC2XOj.png) * OPA3692 @0.1Vpp/1MHz * ![](https://i.imgur.com/5whh2d0.png) The Same to above (empty VME)chassis grounding ## 6. Lab521 grounding but has touched shileding chassis * ![](https://i.imgur.com/3sTpjd5.png) * OPA2674 @0.1Vpp/1MHz: Touch chassis * ![](https://i.imgur.com/6P6EnDM.png) * OPA2674 @0.1Vpp/10MHz: Touch chassis * ![](https://i.imgur.com/skLzy81.png) * OPA2674 @0.1Vpp/1MHz: General * ![](https://i.imgur.com/9X3SlwC.png) * OPA2674 @0.1Vpp/10MHz: General * ![](https://i.imgur.com/TT9jFBE.png) ## 7. Grounding: Lab510 vs Lab521 * Connect Probe and its GND to GND * Touch the board and the Aluminum panel -> The same result * ![](https://i.imgur.com/HEDhfw7.jpg) * ![](https://i.imgur.com/UEixMFS.png) * Lab510 * ![](https://i.imgur.com/9teS3aK.png) * Lab521 * ![](https://i.imgur.com/rtsuJZX.png) * t-domain (Blue-line): * Can't see any useful infomation * f-domain/Spectrum (orange-line): * 10M/1M Hz exist noise * I guess that testing HF-Analog will get bad result on the lab-510 * Antenna: B4F -> 12F??? ## 8. Lab521 grounding but has cover shileding chassis * ![](https://i.imgur.com/9HcBgej.png) * OPA2674 @10MHz/0.1Vpp * ![](https://i.imgur.com/wLfzeob.png) * OPA2674 @1MHz/0.1Vpp * ![](https://i.imgur.com/VtxcF1B.png) * OPA2674 @10MHz/0.1Vpp Enlarge * ![](https://i.imgur.com/JczIZ13.png) * OPA2674 @1MHz/0.1Vpp Enlarge * ![](https://i.imgur.com/G121Ygc.png) ###### tags: `CDCFEReport` `DeWei`